6.5 Filling time
The filling time for a battery depends on the electrolyte level, the ambient temperature
and the filling pressure. Filling ends automatically. The water supply line must be
disconnected from the battery when the water has been filled.
6.6 Water quality
Z The quality of the water used to fill up electrolyte must correspond to purified or
distilled water. Purified water can be produced through distillation or ion
exchangers and is then suitable for the production of electrolyte.
6.7 Battery tubing
The tubing of the individual plugs is in accordance with the existing electric circuit. No
changes should be made.
6.8 Operating temperature
Batteries with automatic water replenishment systems should only be stored in rooms
with temperatures > 0°C, as otherwise the systems could freeze.