1113.GB
E 18
LEDs 18-20 are located in key fields 1-3 (see Section 5.2)
No. Function Range of
Setting
Standard
Setting
Comments
Procedure
Code Lock
002 Change Operator Code 0000 - 9999
or
00000 - 99999
or
000000 - 999999
(LED 18 flashes)
Enter current code
Confirm (Set)
(LED 19 flashes)
Enter new code
Confirm (Set)
(LED 20 flashes)
Repeat code entry
confirm
003 Delete Operator Code 0000 - 9999
or
00000 - 99999
or
000000 - 999999
(LED 19 flashes)
Enter code
Confirm (Set)
(LED 20 flashes)
Repeat code entry
Confirm (Set)
004 Delete code memory
(Deletes all user codes)
3265 3265 = delete
other inputs= do not
delete
010 Automatic time cutout 00 - 31 00 00 = no cutout
01 to 30 =
Cutout time in
minutes
31 = Cutout after
10 seconds
1113.GB
E 18
LEDs 18-20 are located in key fields 1-3 (see Section 5.2)
No. Function Range of
Setting
Standard
Setting
Comments
Procedure
Code Lock
002 Change Operator Code 0000 - 9999
or
00000 - 99999
or
000000 - 999999
(LED 18 flashes)
Enter current code
Confirm (Set)
(LED 19 flashes)
Enter new code
Confirm (Set)
(LED 20 flashes)
Repeat code entry
confirm
003 Delete Operator Code 0000 - 9999
or
00000 - 99999
or
000000 - 999999
(LED 19 flashes)
Enter code
Confirm (Set)
(LED 20 flashes)
Repeat code entry
Confirm (Set)
004 Delete code memory
(Deletes all user codes)
3265 3265 = delete
other inputs= do not
delete
010 Automatic time cutout 00 - 31 00 00 = no cutout
01 to 30 =
Cutout time in
minutes
31 = Cutout after
10 seconds

Table of Contents