4.2.1 Starting procedure for the DFG
Procedure
Insert the key in the key switch (76). Set
key switch to “I”.
The pre-heat indicator lamp (91) lights up
and goes out automatically as soon as
the required pre-heat time (approx. 4
seconds) has been reached.
All the indicators light up briefly to test
operation.
Z All the indicators except for the engine oil
pressure display (82), parking brake
indicator (86), indicator lamp for neutral
(90) and charge current indicator (88)
should go out after a short while. If not,
stop the start-up process and rectify the
fault.
Now set the ignition / starter key to the "II"
position.
Z Only apply the starter for a maximum of
15 seconds without interruption. The
Industrial truck contains a restart blocking
mechanism which prevents it from
starting again while the engine is running.
Release the key as soon as the engine
starts. It automatically reverts to the "I"
position.
Z All indicators lights except for neutral
setting (90) and parking brake (86)
should go out as soon as the engine
starts. If not, stop the engine immediately
and rectify the fault.
The truck is now ready for operation.
0
I
II
76
88
82 86
91
90

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Jungheinrich TFG 320 and is the answer not in the manual?

Jungheinrich TFG 320 Specifications

General IconGeneral
BrandJungheinrich
ModelTFG 320
CategoryForklifts
LanguageEnglish

Related product manuals