To connect and configure the switch from the console:
1. Set the following values on the console server or PC:
Baud rate—9600
Flow control—none
Data—8
Parity—none
Stop bits—1
DCD state—disregard
2. Connect the console port on the rear panel of the switch to a laptop or PC by using the RJ-45 to DB-9 serial port adapter.
NOTE: You can also use the mini-USB port on the front panel to connect the switch to a laptop or PC (see the
documentation at https://www.juniper.net/documentation/en_US/release-independent/junos/topics/task/installation/
port-ex-series-mini-usb-management-console-connecting.html).
3. At the Junos OS shell prompt root%, type ezsetup.
4. (Optional) Enter the hostname.
5. Enter the root password that you want to use for this device.
6. When prompted, reenter the password.
7. Enable the SSH and Telnet services.
NOTE: You will not be able to log in to the switch as the root user through Telnet. Root login is allowed only through
SSH.
The default option for SSH is yes. Press Enter to accept the default option and enable SSH.
The default option for Telnet is no. At the prompt, enter yes and press Enter to enable Telnet.
8. Configure in-band management or out-of-band management:
In in-band management, you configure a network interface or an uplink module (expansion module) interface as the
management interface and connect it to the management device.
In this scenario, can do either of the following:
Use the automatically created VLAN named default for management of all data interfaces as members of the default
VLAN. Specify the management IP address and the default gateway.
Create a new management VLAN. Specify the VLAN name, VLAN ID, management IP address, and default gateway. Select
the ports that must be part of this VLAN.
In out-of-band management, you use a dedicated management channel (MGMT port) to connect to the management
device. Specify the IP address and gateway of the management interface. Use this IP address to connect to the switch.
9. (Optional) Specify the SNMP read community, location, and contact to configure SNMP parameters.
10. (Optional) Specify the system date and time. Select the time zone from the list.
Copyright © 2018, Juniper Networks, Inc.10
EX4300 Switch Quick Start

Other manuals for Juniper EX4300

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper EX4300 and is the answer not in the manual?

Juniper EX4300 Specifications

General IconGeneral
ModelEX4300
Virtual ChassisYes, up to 10 members
Layer 3 RoutingYes
10GBASE SFP+ Ports4
Jumbo Frames9216 bytes
MAC Address Table Size32, 000
Operating SystemJunos OS
Uplink Ports4 x 10GBASE SFP+
Power SupplyAC or DC options
Operating Temperature0°C to 45°C (32°F to 113°F)
Input Voltage100-240V AC
Operating Relative Humidity5 to 90% RH, non-condensing
Management OptionsCLI, Web UI, Junos Space
RedundancyYes, power supply and fans
Storage Temperature-40°F to 158°F (-40°C to 70°C)
Ports24 or 48

Related product manuals