The configured parameters are displayed.
11. Enter yes to commit the configuration.
The configuration is committed as the active configuration for the switch.
You can now log in by using the CLI and continue configuring the switch.
Safety Warnings Summary
This is a summary of safety warnings. The complete list of warnings, including translations, is available at
https://www.juniper.net/documentation/en_US/release-independent/junos/information-products/pathway-pages/ex-series/product/.
WARNING:
Failure to observe these safety warnings can result in personal injury or death.
Permit only trained and qualified personnel to install or replace switch components.
Perform only the procedures described in this quick start and the EX Series documentation. Other services must
be performed only by authorized service personnel.
Before installing the switch, read the planning instructions in the EX Series documentation to make sure that the
site meets power, environmental, and clearance requirements for the switch.
Before connecting the switch to a power source, read the installation instructions in the EX Series documentation.
Installing the switch requires one person to lift the switch and a second person to install the mounting screws.
If the rack has stabilizing devices, install them in the rack before mounting or servicing the switch in the rack.
Before installing or after removing an electrical component, always place it component-side up on an antistatic
mat placed on a flat, stable surface or in an antistatic bag.
Do not work on the switch or connect or disconnect cables during electrical storms.
Before working on equipment that is connected to power lines, remove jewelry, including rings, necklaces, and
watches. Metal objects heat up when connected to power and ground and can cause serious burns or become
welded to the terminals.
Power Cable Warning (Japanese)
The attached power cable is only for this product. Do not use this cable for another product.
Contacting Juniper Networks
For technical support, see http://www.juniper.net/support/requesting-support.html.
Juniper Networks, the Juniper Networks logo, Juniper, and Junos are registered trademarks of Juniper Networks, Inc. in the United States and other countries.
All other trademarks, service marks, registered marks, or registered service marks are the property of their respective owners. Juniper Networks assumes no
responsibility for any inaccuracies in this document. Juniper Networks reserves the right to change, modify, transfer, or otherwise revise this publication
without notice. Copyright © 2019 Juniper Networks, Inc. All rights reserved. Rev. 01, May 2019.
EX4300 Switch Quick Start

Other manuals for Juniper EX4300

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper EX4300 and is the answer not in the manual?

Juniper EX4300 Specifications

General IconGeneral
ModelEX4300
Virtual ChassisYes, up to 10 members
Layer 3 RoutingYes
10GBASE SFP+ Ports4
Jumbo Frames9216 bytes
MAC Address Table Size32, 000
Operating SystemJunos OS
Uplink Ports4 x 10GBASE SFP+
Power SupplyAC or DC options
Operating Temperature0°C to 45°C (32°F to 113°F)
Input Voltage100-240V AC
Operating Relative Humidity5 to 90% RH, non-condensing
Management OptionsCLI, Web UI, Junos Space
RedundancyYes, power supply and fans
Storage Temperature-40°F to 158°F (-40°C to 70°C)
Ports24 or 48