no impact on the traffic. To solve this issue, take the PIC offline and bring it back
online. [PR/516411: This issue has been resolved.]
On an M120, M7i, or M10i router with Enhanced CFEB running JUNOS Release
10.0 and a VRF routing instance configured with vrf-table-label, the VPN traffic
might not flow when an ATM II IQ PIC is used for a core-facing link. [PR/516485:
This issue has been resolved.]
When a Frame Relay interface goes down, the interface statistics might still
indicate that the data-link connection identifier (DLCI) is active. [PR/516497:
This issue has been resolved.]
When the configuration of shaping and scheduling is added or removed from
the CLI, the traffic from the other PE routers is lost. [PR/517320: This issue has
been resolved.]
On IQ2 and IQ2E 10GE PICs operating in WAN-PHY mode, the path trace
information does not get transmitted to the remote end. [PR/518331: This issue
has been resolved.]
When the centralized configuration management (CCM) interval is set to 1m or
above, the CCM flaps for an incorrect hold_time adjacency entry. [PR/520064:
This issue has been resolved.]
The CE_SUPPORT-DCD crashes when a commit is performed. [PR/521380: This
issue has been resolved.]
When one of two Ethernet connections to another Routing Engine is not present,
the mastership is not switched. [PR/521833: This issue has been resolved.]
When multiple routed IPsec tunnels are configured, and the tunnel with the
inside-service-interface defined in the service-set goes down, the other tunnels
with the ipsec-inside-interface configured only in the IPsec rules can stop
forwarding traffic until the main tunnel comes back up. [PR/524935: This issue
has been resolved.]
When M120 Type 1 FPCs are configured for 2:1 FPC:FEB mapping, and one of
the FPCs restarts, the restarting FPC might not initialize properly and result in a
small percentage of packet loss for all interfaces on that FPC. As a workaround,
restart the FPC until the problem stops. [PR/529994: This issue has been
resolved.]
Layer 2 Ethernet Services
The bpdu-block-on-edge configuration may not work properly when the interface
is configured as 'edge' under the [edit protocols vstp vlan vlan-id interface
interface-name] hierarchy level. [PR/522198: This issue has been resolved.]
Network Management
After an LCC switchover, the SNMP process fails to send traps with resource
temporarily unavailable errors. [PR/493385: This issue has been resolved.]
Memory leaks might occur on the mib2d. [PR/517565: This issue has been
resolved.]