On 40x1 Gigabit Ethernet PICs, very short fragments of fragmented TCP, UDP,
and ICMP packets may be incorrectly dropped with the diagnostic L4 length too
short. [501526: This issue has been resolved.]
The configured TTL set for GRE traffic is set properly for locally generated Routing
Engine packets, but is not set properly for transit packets. There is no
workaround. [PR/502087: This issue has been resolved.]
During a link UP/DOWN transition, jsscd may crash as a result of a NULL message
dereferencing by jsscd. [PR/502745: This issue has been resolved.]
In JUNOS Release 10.1, if the Neo MPCs power up while the A-DPCs are offline,
and if ISSU is performed, the MPCs will crash. [PR/502837: This issue has been
resolved.]
When an ATM AIS cell is received from the virtual channel under vlan-vci-ccc
encapsulation, the logical interface will be incorrectly marked down. There is no
workaround. [PR/503653: This issue has been resolved.]
When the show lacp interface aex command is used for a nonexistent AE interface,
no error is returned. [PR/503806: This issue has been resolved.]
The yellow marking for the three-color-policers is incorrect. Even after the excess
burst buffer is full, the yellow counters continue to increment at the same rate
as the green buffers. [PR/504192: This issue has been resolved.]
As a result of an incorrect configuration for the DDR memory controller, errors
might be reported when a Trio-based MPC or MX80 boots. There is no
workaround. [PR/505490: This issue has been resolved.]
Under certain circumstances, the E3 IQ PIC might report bogus CCV, CES, and
CSES alarms. [PR/505921: This issue has been resolved.]
The JUNOS Software may accept duplicate data-link connection identifiers (DLCIs)
configured on the same physical interface. [PR/506908: This issue has been
resolved.]
When native-vlan-id is configured for aggregated interface with the child links on
an IQ2 PIC, the LACP are dropped and the links go down. [PR/507040: This issue
has been resolved.]
The show interfaces diagnostics optics interface command does not display the
unit of measurement when the received power is in a very low range (power <
5e-10). It shows the value of 0.00 without any unit of measurement. [PR/507653:
This issue has been resolved.]
On MX Series routers, the chassisd crashes when the SCB is taken offline and
removed. [PR/510950: This issue has been resolved.]
On M7i and M10i routers, the syncer process writes to the file
/var/rundb/chassisd.dynamic.db every 30 seconds. [PR/511901: This issue has
been resolved.]
Under certain circumstances, the chassisd process might crash on a backup
Routing Engine while a configuration is commited. [PR/512044: This issue has
been resolved.]
Due to a flaw in implementation, the execution of the show interfaces
mac-database command causes the IQ2 PIC to reboot with the core. [PR/513407:
This issue has been resolved.]
Issues in JUNOS Release 10.1 for M Series, MX Series, and T Series Routers 75
Issues in JUNOS Release 10.1 for M Series, MX Series, and T Series Routers