The cable with very low resistance (indicating a closed circuit) to chassis ground will be connected to the V+
(return) DC power input terminal.
c. Remove the clear plastic cover from the terminal studs on the faceplate.
d. Remove the screws on the terminals by using a Phillips (+) screwdriver, number 2.
e. Secure each positive (+) DC source power cable lug to a RTN (return) terminal. Secure each negative (–) DC source
power cable lug to a -48V (input) terminal.
f. Replace the clear plastic cover over the terminal studs on the faceplate.
g. Remove the tape from the switch handle of the circuit breaker on the panel board that services the DC circuit and
switch the circuit breaker to the ON (|) position.
3. Turn on the power to the AC power receptacle.
4. Note the following LED indications. Wait until the STATUS LED is solid green before proceeding to the next step.
Table 6: LED States
StateLED
•
Solid green (receiving power).POWER
•
Solid green (operating normally).STATUS
•
Amber (operating normally–the LED might glow amber if a rescue configuration is
not set. This is not a panic condition).
ALARM
•
Off (Mini-PIM not present or not detected).
•
Solid green (Mini-PIM is operating normally).
•
Red (Mini-PIM hardware failure or counterfeit check failed).
MPIM-1 and MPIM-2
•
Off (HA not enabled).
•
Solid green (all HA links are available).
HA
•
Solid green (redundant power supply is operating normally).RPS
The ACE LED is not functional.ACE
•
Solid green (the services gateway is transferring data to or from the optional storage
device).
STORAGE
9