EasyManuals Logo

Junkers ZWC 24-3 MFK User Manual

Junkers ZWC 24-3 MFK
87 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #28 background imageLoading...
Page #28 background image
153 Transformator Enter(230V)=48?
Exit 9VDC:1?
Exit 25 VDC:1,4?
312 Fuse T 1,6 A,
24 V DC
At the fuse
At the fuse
0 ? - - -
313
Fuse T 0,5A,
5 V DC
? - - -
413
Flow rate
Sensor(turbine)
White sock
Connector: 9-10-11
Cable colour :red
yellow / black
9,6 Hz = 1,5 l/min.
68,7 Hz. = 10 l/min.
6.d ± 2 Hz
± 6 Hz
-
Pos. Definition
Measurement
Point
Value Expected
Heatronic
Parameter
Tolerance Explanation
Tab. 4 Electrial values for ZWC / ZSC 18/24/28-3 MFK / MFKP and ZWE 24/28-5 MFK types
Measure
when the
trafo
28 | Electrial Values
6 720 660 238 (2008/07)
28