EasyManuals Logo

Junkers ZWC 24-3 MFK User Manual

Junkers ZWC 24-3 MFK
87 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #38 background imageLoading...
Page #38 background image
1. No:
2.
Yes:
2.
3.
Yes:
Yes:
If C4 still flashing 3.
If C4 still flashing 4.
No:
No:
3.
4.
4. Electronic card is out of order
Check if APS is working or not
C4IS FLASHING
APS contacts remain closed
Control StepOrder Measure
Switch off the appliance
Cut mains supply
Change the electronic card
Connect to mains supply
Switch on the appliance
6 720 660 238 (2008/07)
38
38 | Troubleshooting
blocked or check if there is condensation
Check if APS hoses are damaged or
in hoses?
If C4 still flashing? 2.
Turn off the appliance
Clean and dry APS hoses.
Switch on the appliance
Turn off the appliance
Change APS
Switch on the appliance
Check if the 20 poled connection
cable damaged.
Check 7-8 pin for any intermittent
contact
Change the cable harness
Switch on the appliance.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Junkers ZWC 24-3 MFK and is the answer not in the manual?

Junkers ZWC 24-3 MFK Specifications

General IconGeneral
BrandJunkers
ModelZWC 24-3 MFK
CategoryBoiler
LanguageEnglish

Related product manuals