8.2 DHW NTC
8.3 Flue gas NTC
8.4 Combustion chamber NTC
Temperature
(ºC)
Resistance (
? )
0 33242
10 19947
20 12394
30 7947
40 5242
50 3548
60 2459
70 1740
80 1256
90 923
Tab. 56
0 28250
0 330
20 12161
25 110
40 5736
60 24,08
60 2949
80 11,77
80 1634
100 6,12
100 961,4
120 3,37
120 595,2
140 1,95
140 386,2
160 1,17
160 260,2
165 1,04
Tab. 57