JVa Z14/Z14R ManUal
Command Key1 Key2 Keys 3 and 4 Key5
Low Power Mode Power
Level
0 2 00 01 02 03 04 05 06 07 08 09 #
Percentage of High Power Mode Power Level
0.5% 1.0% 1.5% 2.0% 2.5% 3.0% 3.5% 4.0% 4.5% 5.0%
Return Fence Alarm
Voltage For High Power
Mode
0 3 00 01 02 03 04 05 06 07 08 09 #
Fence Alarm Voltage (kV) Conventional
1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0
Fence Alarm Voltage (kV) Bi-Polar
1.5 1.8 2.1 2.4 2.7 3.0 3.3 3.6 3.9 4.2
Return Fence Alarm Volt-
age For Low Power Mode
0 5 00 01 02 03 04 #
300 Volts 500 Volts 700 Volts 900 Volts 1100 Volts
Bad/Missed Pulse Count
Before Alarm Triggers
0 6 00 01 02 03 04 05 06 07 08 09 #
0 1 2 3 4 5 6 7 8 9
Battery Alarm Voltage
(olts). Alarm Value Shown,
Reduced Power is 1V less
0 7 00 01 02 03 04 05 06 07 08 09 #
9.0 9.5 10.0 10.5 11.0 11. 5 12.0 12.5 13.0 13.5