JVA Z14/Z14R User Manual
0 None
+1 Siren codes
+2 Gate delay type
+4 4800 baud
+8 9600 baud
8.6.17
This option sets the time which must elapse before another alarm will sound
after the rst alarm has timed out (gone completely through its cycles without
being turned o).If an event occurs (such as a low fence voltage) which triggers
the siren, any other events which would otherwise trigger the siren (such as a
gate alarm) will be ignored while the siren is sounding and until after the Auto
Re-arm time has passed. A setting of 0 will disable Auto Re-arm.
If this time is set to less than the Siren O Time, the Energiser may re-arm in the
“O” time and the number of Siren Cycles will be reduced.
Time
0 0 Seconds
(Immediate)
1 30 Seconds
2 1 Minute
3 2 Minutes
4 3 Minutes
5 4 Minutes
6 5 Minutes
7 6 Minutes
8 7 Minutes
9 Disabled – Do not
auto rearm