Page 13www.jva-fence.com
JVa Z14/Z14R ManUal
Command Key1 Key2 Keys 3 and 4 Key5
Combined Options 1
(add up the options you
want. e.g. for Max Power
and Limit output:
2 + 4 = 6 Therefore enter
06 for keys 3 and 4
1 6 +2 +4 +8 +16 +32 #
Maximum
Power at all
times
Limits out-
put to 2.5J
per Zone
Enables IR
Tamper.
Stop slaves
on comms
fail
Stop Ener-
giser send-
ing alarm
memory
Anti Bridging threshold 1 7 Enter in the percentage dierence required to trigger the Anti-Bridging
alarm. e.g. if you require a 10% change in return voltage to trigger the
alarm, enter 10 for keys 3 and 4
#
Combined Options 2
(like Combined Options 1)
1 8 +1 +2 +4 +8 #
Siren Codes
(Chirps 1 for
armed, twice for
disarmed)
Gate Delay Type 4800 baud 9600 baud
Auto Re-arm Time
(S=Seconds, M = Minutes,
D=Disabled
2 0 00 01 02 03 04 05 06 07 08 09 #
0S 30S 1M 2M 3M 4M 5M 6M 7M D
Relay 1 2 1 Options Explained under “1.3.1 Relay Functions” Default is 08 #
Relay 2 2 2 Options Explained under “1.3.1 Relay Functions” Default is 09 #