EasyManua.ls Logo

JVA Z14 - Page 13

JVA Z14
96 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 12
© JVA Technologies Pty. Ltd.
Page 13www.jva-fence.com
JVa Z14/Z14R ManUal
Command Key1 Key2 Keys 3 and 4 Key5
Combined Options 1
(add up the options you
want. e.g. for Max Power
and Limit output:
2 + 4 = 6 Therefore enter
06 for keys 3 and 4
1 6 +2 +4 +8 +16 +32 #
Maximum
Power at all
times
Limits out-
put to 2.5J
per Zone
Enables IR
Tamper.
Stop slaves
on comms
fail
Stop Ener-
giser send-
ing alarm
memory
Anti Bridging threshold 1 7 Enter in the percentage dierence required to trigger the Anti-Bridging
alarm. e.g. if you require a 10% change in return voltage to trigger the
alarm, enter 10 for keys 3 and 4
#
Combined Options 2
(like Combined Options 1)
1 8 +1 +2 +4 +8 #
Siren Codes
(Chirps 1 for
armed, twice for
disarmed)
Gate Delay Type 4800 baud 9600 baud
Auto Re-arm Time
(S=Seconds, M = Minutes,
D=Disabled
2 0 00 01 02 03 04 05 06 07 08 09 #
0S 30S 1M 2M 3M 4M 5M 6M 7M D
Relay 1 2 1 Options Explained under “1.3.1 Relay Functions” Default is 08 #
Relay 2 2 2 Options Explained under “1.3.1 Relay Functions” Default is 09 #

Table of Contents