25
Item
Measuring
instrument
Test point Ad justment part Description
6. TINT [Method of adjustment without measuring instrument]
NTSC 3.58 T INT
1. Input a NTSC 3. 58 full fie ld colo ur b ar signa l ( 75% white) .
2. En ter th e SERVICE MENU.
3. Select 2. V/C f rom SERVICE ME NU.
4. Select 6. TINT with t he ME NU ▼/▲ key.
5. Set the initial s etting value of NTSC 3.58 with the MENU - / +
key.
6. If you ca nn ot get the best tin t with th e in itial s ettin g va lue, ma ke
fine adjustment until you get the best tint.
Ad ju st ment
of TINTⅠ
ⅠⅠ
Ⅰ
Signal
generator
Remote
control unit
NTSC 4.43 TINT
When NTSC 3.5 8 is set, NTSC 4. 43 will be aut omatica lly se t at t he
resp ective va lues .
6. TINT [Method of adjustment using measur ing instrument]
NTSC 3.58 T INT
1. Input a NTS C 3.58 f ull field colo ur bar signa l (75% white).
2. En ter th e SERVICE MENU.
3. Select 2. V/C f rom SERVICE ME NU.
4. Select 6. TINT with t he ME NU ▼/▲ key.
5. Set the initial s etting value of NTSC 3.58 with the MENU - / +
key.
6. Con nect th e osc illosc ope be twee n TP -47G /R a nd TP- E. (#).
7. Adjust NTSC 3.58 TINT to bring the value of (B) in the
illustration +9V(W- Cy). (Voltage value be twee n (W) an d ( Cy))
Ad ju st ment
of TINTⅡ
ⅡⅡ
Ⅱ
Signal
generator
Oscillo-
sc ope
Remote
control unit
TP-47G/R
TP-E (#
##
#)
[CRT
SOCKET
PWB]
NTSC 4.43 TINT
When NTSC 3.5 8 is set, NTSC 4. 43 will be aut omatica lly se t at t he
resp ective va lues .
W
Y
C