4.4.3 DESTINATION WRITING
Note :
Perform this operation during standby mode.
PROCEDURE
(1) Run Scaler Service Software.
(2) From the COM Port, select the [Connect to FP] and con-
nect PC and projector.
(3) Select the destination from the Location, and write the
destination.
4.4.4 TRANSFERRING CMS DATA FROM DD SUB PWB
Note :
Perform the operation with the power ON.
Input the signal from external equipment.
PROCEDURE
(1) Run the VP Writer application program.
(2) Select a COM Port.
(3) Click "Write".
(4) CMS data is transferred from the DD SUB PWB.