Manual Product description
B-eco 04043988 - 02/2014 15
3.2.5 Power supply
PoE (Power over Ethernet)
Power supply of the terminal via the 8-wire Ethernet cable (max. 100 m).
• Corresponds to IEEE 802.3 af
• Power consumption class 3, max. power consumption 12.95 W
• Supported powering processes:
− Spare pair powering
over (Fast Ethernet free) wire pairs 4/5 and 7/8
− Phantom powering
over RX wires (1/2) and TX wires (3/6)
Power supply is superimposed to the data signal
3.2.6 Uninterruptible power supply (option)
The optional uninterruptible power supply (UPS) guarantees operation for up to
15 minutes or approx. 200 bookings in case of power failure. Whatever occurs first.
Requirement: New battery, 90% charged, temperature 20 - 25 °C.
The battery is completely charged after 10 hours.
3.2.7 Environmental conditions
• Ingress protection according to IEC 60529:
− IP30
− IP54 (Option for devices with RFID reader)
• Relative humidity:
− 5% to 95%, non-condensing
• Environmental temperature:
− 0 °C – +40 °C (operation)
− -25 °C – +70 °C (storage)