Installation Manual
38 04043988 - 02/2014 B-eco
5.5 Connections
In1
In2
GND
NO
C
NC
GND
OUT
Ethernet
PoE
IN
1 2
3
4
1 RJ45 Ethernet network connection
Communication with the host and power supply of the terminal via PoE
2 Terminal block for the relay output
Max. contact rating 30 V AC / DC; 2 A
Only voltages from limited power sources according to EN 60950-1 may be
applied.
The relay can be used to trigger the door opener. For door openers, which are
supplied with direct current, a freewheeling diode must be connected in
parallel to suppress interference (in reverse direction). A varistor must be
connected in parallel to AC door openers.
3 RJ45 connection for an external reader or the optional swipe card reader
4 Digital inputs
The inputs are connected to common ground using a simple switch or relay
contact.