11. Return the unlocking slide (C) over the unlocking slide studs (A) while making certain the
ve toes (G) are engaged in the ve gear pockets (F). It may be necessary to adjust each gear
(D) slightly to make proper alignment between toes and gear slots (see gures 6 & 7).
Re-secure the "E" ring on the stud (A). Your chamber will now resemble gure 7 and is ready
for reassembly with the lock housing.
REASSEMBLY
1. Re-secure the chamber cover (A) marked ILCO UNICAN. Make sure the staked joints (B)
(see gure 2) on both end plates t through both slots on the chamber cover.
2. Re-secure the shaft bushing (C) with at side facing up (see gure 8).
3. Secure the combination chamber with the two Phillips head screws (G) you removed earlier.
4. Re-secure the chamber links (A) onto the control shaft.
5. Replace the guide bracket (D) by aligning the clutch linkage in the guide bracket and secure
with the two Phillips head screws (F) previously removed.
6. Replace the back plate and secure it with the six back plate screws.
SETTING THE COMBINATION
Do not attempt to set a combination until the complete unit has been reassembled.
Perform the following steps in the order shown.
1. Turn the outside lever once to the stop position and then release.
2. Enter the new combination.
3. Turn the outside lever to the stop position, make sure the latch is fully retracted, then release
the lever.
KAA1166 0108

Other manuals for Kaba Simplex LP1000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kaba Simplex LP1000 Series and is the answer not in the manual?

Kaba Simplex LP1000 Series Specifications

General IconGeneral
BrandKaba
ModelSimplex LP1000 Series
CategoryDoor locks
LanguageEnglish

Related product manuals