Operating Instruction I
nEnglish translation of German original
These instructions form part of the product and must be carefully read, observed and stored in a place which is freely accessible at all
times.
S; XL
KACO blueplanet 87.0 TL3
KACO blueplanet 92.0 TL3
KACO blueplanet 110 TL3
KACO blueplanet 125 TL3
KACO blueplanet 137 TL3
KACO blueplanaet 150 TL3
Authorised electrician
Important safety instructions

Table of Contents

Questions and Answers

  • C
    Christian BerryAug 18, 2025
    Why Kaco blueplanaet 150 TL3 doesn't feed maximum power into the grid despite high radiation?
    • R
      Robin RodriguezAug 18, 2025
      If your Kaco inverter isn't feeding maximum power into the grid despite high radiation, it could be due to particular ambient conditions. Ensure sufficient cooling of the unit. Also, remove any foreign bodies present on the device and clean the cooling fins.
  • C
    Casey MorganAug 20, 2025
    What to do if the grid fuse trips with Kaco blueplanaet 150 TL3 Inverter?
    • A
      Amanda RodriguezAug 20, 2025
      If the grid fuse trips when using your Kaco Inverter, it may be because the grid fuse capacity is too low. Select a backup fuse with a capacity somewhat higher than the device’s maximum feed-in current. If this doesn't resolve the issue, there may be hardware damage, in which case you should contact KACO Service to test the hardware.
  • N
    nicholas91Aug 22, 2025
    How to troubleshoot Kaco blueplanaet 150 TL3 when the LEDs do not light up?
    • M
      Mark OwenAug 22, 2025
      If the LEDs on your Kaco Inverter do not light up, it could be due to the grid voltage not being available. Check whether the DC and AC voltages are within the permitted limits. If the issue persists, notify KACO Service.
  • P
    Peter DavisAug 26, 2025
    What to do if Kaco blueplanaet 150 TL3 Inverter stops feeding into the grid shortly after being switched on?
    • C
      Christy LaneAug 26, 2025
      If your Kaco Inverter stops feeding into the grid shortly after being switched on, even with sunlight present, the cause may be defective circuit-breakers in the device. Ensure that there is sufficient PV generator power. Another potential cause is a defective grid separation relay, which should be replaced by KACO Service. If neither of these solutions work, notify KACO Service.
  • S
    Samantha HarmonAug 27, 2025
    Why is Kaco blueplanaet 150 TL3 Inverter active but not connected to the grid?
    • D
      darius97Aug 27, 2025
      If your Kaco Inverter is active but not connected to the grid, it might be due to a grid-feed interruption caused by a grid fault. Change the grid parameters within the permitted operating limits.
  • C
    Crystal HowellAug 30, 2025
    What causes an impossible daily peak value on Kaco Inverter display?
    • J
      Jody BullockAug 30, 2025
      If your Kaco Inverter displays an impossible daily peak value, it is likely due to faults in the grid. To reset the value immediately, switch the device off by disconnecting it from the grid and switching off the DC, then switch it back on.
  • C
    cheryl31Sep 1, 2025
    What does 'Fault in fan 2' mean on my Kaco blueplanaet 150 TL3 Inverter?
    • A
      Ashley GreerSep 1, 2025
      If your Kaco Inverter displays 'Fault in fan 2', the fan is malfunctioning. Notify KACO Service! With a defective fan, the power is reduced to 50% to avoid the device being destroyed.
  • J
    Jeremy ThomasSep 4, 2025
    What does 'Fault in fan 3' mean on my Kaco Inverter?
    • A
      Anthony JonesSep 4, 2025
      If your Kaco Inverter displays 'Fault in fan 3', the fan is malfunctioning. Notify KACO Service! With a defective fan, the power is reduced to 50% to avoid the device being destroyed.
  • J
    James SalazarSep 6, 2025
    What to do if there is a fault in fan 1 of Kaco Inverter?
    • J
      jrobinsonSep 6, 2025
      If there is a fault in fan 1 of your Kaco Inverter, it means that the fan is malfunctioning. Replace defective fan.
  • S
    Savannah OrrSep 9, 2025
    Why don't daily yields correspond to the yields on the feed-in meter of Kaco blueplanaet 150 TL3?
    • P
      posborneSep 9, 2025
      If the daily yields on your Kaco Inverter do not correspond to the yields on the feed-in meter, it is due to tolerances of the measuring elements in the device. No action is required.

Kaco blueplanaet 150 TL3 Specifications

General IconGeneral
Modelblueplanet 150 TL3
AC voltage range310 V - 480 V
Number of MPP trackers1
Protection ClassIP21
Maximum DC Input Voltage1000 V
Nominal AC Voltage400 V
Operating Temperature Range-25 °C to +60 °C
Warranty5 years
TypeString Inverter
Rated Output Power150 kW
Max. apparent AC power150 kVA
Nominal AC Output Power150 kW
Nominal AC Frequency50 Hz / 60 Hz