1. Purpose
Kitchen central heating solid fuel boiler Kalvis-4 (the boiler), is an
interrupted combustion unit. It is mainly used to heat living premises where
central heating system is installed with forced circulation and with open or
closed expansion system.
Additionally, boiler can be used for food cooking.
2. Safety precautions
Boiler can be operated by adults, well-familiar with its design and
this technical specification.
In the case of fire in the premises or in the chimney, close air supply to
the boiler and call fire rescue service (tel. 112). If possible, remove burning
fuel and ember from combustion chamber into a sealed or water-filled
container (keep away from water steam and wear protective gloves).
It is prohibited:
To arbitrarily change the design of the boiler.
To use a common ventilation system for the boiler flue outlet!
To ignite boiler with flammable liquids (petrol, kerosene, etc.).
To dry fuel and other easily ignitable items near or on the boiler.
To leave alone or entrust with boiler care: children, the disabled and
untrained persons.
To open or leave open the boiler door during the boiler stoking.
To start the boiler without filling the heating system with water (water in
the heating system and the boiler must not freeze).
To connect the boiler to a closed system without a safety valve that
prevents the system from exceeding the pressure by more than 1.5 bar
(0.15 MPa).
When operating the boiler, to close the feed and return line valves.
To dispose still burning ashes near residential and commercial buildings.
It is prohibited to stoke the boiler with:
fine wood waste (dust), this causes explosion risk or spark discharge
from chimney;
waste (household waste);
furniture waste.