KPC-9612 Version 5.2 July 19, 1994
34
• NDWild ON|OFF {OFF}
When OFF, the KA-Node will only recognize connect requests directed to the MYNODE call. When
ON, connect requests to any SSID of the MYNODE call will be recognized as connects to the KA-
Node, if that SSID is not being used for any other ID in the KPC-9612.
See also: my alias, my call, my gate, mynode, mypbbs, myrcTnote
• Newmode ON|OFF {ON}
When ON, the KPC-9612 will return to Command Mode if the station on the current I/O stream dis-
connects. The KPC-9612 will not return to Command Mode if the station disconnecting is on a dif-
ferent stream. When OFF, a disconnect will not cause the KPC-9612 to change modes.
See also: connect, disconne, status
• NOmode ON|OFF {OFF}
When OFF and a connection takes place, the KPC-9612 will change to the mode specified by the
CONMODE command. When ON, the KPC-9612 does not change modes when a connect occurs.
See also: conmode, connect
• NText
text
(up to 128 characters) {blank}
This entry specifies the customized text sent with the initial KA-Node sign-on message (when a re-
mote station connects to the KA-Node). Enter any combination of characters and spaces, up to a
maximum of 128 characters. To clear the NTEXT, give the command NTEXT %.
See also: mynode, numnodes
• NUMNODES
n
(
n
= 0 – 26 [depending on RAM]) {0}
This command sets the number of allowable circuits through the KA-Node. The maximum number
allowed will depend on the amount of RAM that is available for node circuits, and will vary based
on the values you specify for PBBS and MAXUSERS. It will also depend on whether or not you have
the MYREMOTE enabled.
See also: mynode
• Oneradio ON|OFF {OFF}
When ON, the presence of carrier detect on either of the two radio ports will prevent both ports
from transmitting (if FULLDUP is OFF). This can be used to operate two different speeds on one
frequency. When OFF, each port of the KPC-9612 detects presence of a signal independent of the
other port.
See also: cd