Display of faults
Faults detected by the control system are shown on the
display of the control unit. The control system classifies
faults in three groups.
Procedure when faults are displayed
n Read off the fault shown on the display
Displayed faults which take up more than 2 lines
can be viewed using the button -1
When several faults have appeared at the same
time, you can use the
to scroll through them
n Faults according to the data in Table 1. Remedying
detected and displayed faults
n Acknowledge fault message by pressing the “ENTER”
button for longer than 3 seconds. Acknowledgment is
not required for position faults.
Fault message of critical faults or less
critical faults:
a Date of fault occurrence
b Time of fault occurrence
c Displayed fault
d of ... faults
e Fault number
f Fault text in display
g Fault text accessible with
button -1
A08/04 15.07 1/1
F01 Machine is not
in start position
a b c d
e f g
G2
Recognised and displayed faults
Display Possible cause Remedy By whom
F1… Machine is not in start position Press button “Start position” on the
control panel for manual operation
Operator
F2… Safety switch of side brushes defective Check switch Operator
F3… Safety switch of roof dryer defective
Fault diagnosis with the positioning light (option)
Recognised and displayed faults
Traffic light signal Fault
orwards 1 blink Machine is not in start position
orwards 2 blinks Safety switch side brushes
orwards 3 blinks Safety switch roof dryer
orwards 4 blinks Air pressure too low
orwards 5 blinks Automatic frost protection (option) is activated

Table of Contents