Maintenance Check the function of the condensate pump each time a tube is
replaced.
Open the bed (Section 5.8) and slowly fi ll the tub of the air-
conditioning unit with water.
Make sure that the water is pumped off periodically. For this test,
the unit must be connected to the mains supply.
By a regular and proper maintenance of the apparatus, you make
a substantial contribution to the safety of the system and to a
long period of trouble-free operation
Illustr. 5-23 Air-conditioning unit and condensation pump
The condensate pump is controlled by the processor in such a
way that, during the tanning session, it is switched on every 5
minutes for 20 seconds each. After the tanning session is over,
this sequence is repeated 3 times.
tanning session
pump
The tube for the condensate should be mounted not higher as in
the tanning bed (power of the pump)!