GB 28
GB
Unit: ampere
Value range: 1,0...1,1 * Inverter rated current
Factory setting: 8,0 A
Adjustment value: in accordance with the motor name plate
Unit: hertz
Value range: 20...100 Hz
Factory setting : 50 Hz
Adjustment value: in accordance with the motor name plate
Unit: rpm
Value range : 100...6000 rpm
Factory setting: 1440 rpm
Adjustment value: in accordance with the motor name plate
You may not enter the motor-synchronous speed
(e.g. 1500 rpm for a 4 pole motor). Ask the manufacturer
for the motor rated speed if you cannot find it on the
name plate.
Unit: volt
Value range: 1...650 V
Factory setting: 400 V
Adjustment value: in accordance with the motor name plate
Unit: 1
Value range: 0,01...1,00
Factory setting: 0,86
Adjustment value: in accordance with the motor name plate
Unit: rpm
Value range: 0,0...6000,0 rpm
Factory setting: 1200,0 rpm
Adjustment value: approx. 80% of the synchronous speed
8. Parameter Description
ASM-Rated Motor Current
ASM-Rated Motor Frequency
ASM-Rated Motor Speed
ASM-Rated Motor Voltage
ASM-Power Factor cos
ϕϕ
ϕϕ
ϕ
Field Weakening Speed