8. Parameter Description
Unit: meter per second
2
Value range: 0,10...2,00 m/s
2
Factory setting: 0,90 m/s
2
Adjustment value: according to comfort
Empirical values: 0,5...0,8 m/s
2
for retirement homes, hospitals,
apartment buildings
0,8...1,2 m/s
2
for office buildings, banks etc
Acceleration
Deceleration Jerk
Unit: meter per second
3
Value range: off, 0,11...9,99 m/s
3
Factory setting: 1,00 m/s
3
Adjusted value: according to comfort
When the deceleration jerk is set too low, parameter
LF.53 is no longer valid.
Deceleration
Unit: meter per second
2
Value range: 0,10...2,00 m/s
2
Factory setting: 0,90 m/s
2
Adjusted value: according to comfort
Stopping Jerk
The stopping jerk determines the ride comfort as it lowers onto the
floor from the path optimization. If the setting LF.54 = off, then the
stopping jerk = deceleration jerk (LF.52)
Level Brake
Unit: meter per second
Value range: off, 0,02...9,99 m/s
Factory setting: off
Adjustment value: according to comfort
Unit: meter per second
Value range: 0,000...0,010 m/s
Factory setting: 0,005 m/s
Adjustment value: 0,005 m/s