EasyManua.ls Logo

KEB COMBIVERT F4-F

KEB COMBIVERT F4-F
66 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
GB 46
GB
Using the rating plate data the inverter determines the motor rated
output in the rated point.
Unit: kilowatt
Factory setting: 0,00 kw
8. Parameter Description
SSM Rated Motor Output
(only display)
SSM Rated Motor Speed
SSM Rated Motor Current
Rated Motor Frequency
Static Current
Unit: rotations per minute (rpm)
Value range: 50 … 6000 rpm
Factory setting: 4000 rpm
Adjusted value: in accordance with the motor name plate
Unit: ampere
Value range: 0,1 A … 1,1* inverter rated current
Factory setting: 3,7 A
Adjusted value: in accordance with the motor name plate
Unit: hertz
Value range: 10 … 600 hz
Factory setting: 200 hz
Adjusted value: in accordance with the motor name plate
Unit: ampere
Value range: 0,1 … 40,0 A
Factory setting: 4,1 A
Adjusted value : in accordance with the motor name plate
Unit: newtonmeter
Value range: 0,1 … 600,0 nm
Factory setting: 5,1 Nm
Adjusted value: in accordance with the motor name plate
SSM Rated Motor Torque
Unit: volt 1000 rotations per minute
Value range: 0 … 2000 v/1000 rpm
Factory setting: 0 V/1000 rpm
Adjusted value: in accordance with the motor name plate
SSM-EMK Voltage
Stabilizer
Unit: ohm
Value range: 0,1 … 50,0
Factory setting: 1,8
Adjusted value: in accordance with the motor name plate
Winding Resistance (RU-V)

Other manuals for KEB COMBIVERT F4-F