Parameter Tables
79
ANTRIEBSTECHNIK
6.3 Pn-Parameter
6.4 uF-Parameter
Size No. Name Adr.
(hex)
P E ro Res. Lower
Limit
Upper
Limit
Default
Value
Unit
Pn 0 Automatic Retry UP 2200 1 0 1 1
Pn 1 Automatic Retry OP 2201 1 0 1 0
Pn 2 Automatic Retry OC 2202 1 0 1 0
Pn 4 LAD Stop Function 2204
10 7 1
Pn 5 LAD Load Level 2205
1 10 200 140 %
Pn 6 LD Voltage 2206
1 200 800 750/375 V
Pn 7 Speed Search Condition 2207
10 15 8
Pn 8 DC Braking Mode 2208
10 9 7
Pn 9 DC Brake Start Frequency 2209
0,0125 0 409,5875 4 Hz
Pn 10 DC Brake Maximum
Voltage
220A
0,1 0 25,5 25,5 %
Pn 11 DC Braking Time 220B
0,01 0 100 10 s
Pn 12 Stall Mode 220C
10 4 1
Pn 13 Stall Level 220D
1 10 200 200 %
Pn 14 Stall ACC/DEC Time 220E
0,01 0 300 10 s
Pn 16 E.dOH Delay Time 2210 1 0 120 60 s
Size No. Name Adr.
(hex)
P E r
o
Res. Lower
Limit
Upper
Limit
Default
Value
Unit
uF 0 Rated Frequency 2300
0,0125 0 409,58 50 Hz
uF 1 Boost 2301
0,1 0 25,5 2 %
uF 4 Delta Boost 2304
0,1 0 25,5 0 %
uF 5 Delta Boost Time 2305
0,01 0 10 0 s
uF 8 DC Voltage
Compensation
2308
••
1 150 650 : off 650 : off V
uF 9 Minimum Frequency For
Modulation
2309
0,0125 0 409,58 0 Hz
uF 11 Carrier Frequency 230B
1 1 In. 3
(16)
4kHz