KEB COMBIVERT H6 Series Specifications

General IconGeneral
SeriesH6
CategoryControl Unit
Input Voltage3-phase, 380-480V AC
Output Voltage0-480V AC
Control ModeV/f control, vector control
Protection FeaturesOvercurrent, overvoltage, undervoltage, overload, short circuit, overtemperature
Communication InterfacesRS485, CANopen, Profibus, Ethernet
Cooling MethodFan cooling
Ambient Temperature-10°C to +40°C
Storage Temperature-25°C to +70°C
Relative Humidity5-95% (non-condensing)
AltitudeUp to 1000 m
Enclosure RatingIP20

Summary

Basic Safety Instructions

Installation Requirements

Instructions for safe installation, including environmental and mounting considerations.

Electrical Connection Safety

Crucial safety procedures for connecting the device electrically to prevent hazards.

Start-Up and Operation Safety

Safety precautions for starting, operating, and handling the device during use.

Product Description

Specified and Unintended Use

Defines the intended application and prohibits misuse of the drive system.

Technical Data

Operating Conditions - Electrical

Details electrical operating conditions and device classification.

Technical Data of AIC Modules

Comprehensive technical specifications for AIC modules across different sizes.

Technical Data of Charging Units H6

Detailed technical data for the H6 charging modules.

Mechanical Installation

Control Cabinet Installation

Guidelines and distances for installing the device in a control cabinet.

Installation and Connection

Front Side Connections Overview

Details the terminal connections on the front side of the device.

Rear Side Connections (Size CS)

Shows rear connections for device sizes C and S, including terminal details.

Rear Side Connections (Size EU)

Shows rear connections for device sizes E and U, including terminal details.

Rear Side Connections (Size GW)

Shows rear connections for device sizes G and W, including terminal details.

Upper Side Device Connections

Details digital inputs/outputs and communication interfaces on the upper side.

Terminal Block X1 E and X1 F Details

Detailed assignment and connection data for terminal blocks X1E and X1F.

Terminal Block X1 A Rear Connections

Details connections for the power unit terminal strip X1A on the rear.

Terminal Block X1 B and PE Connections

Details connections for the braking resistor (X1B) and protective earth (PE).

DC Bus Connection

Instructions for connecting the DC bus between H6 devices using copper bars.

24 V Bus Connection

Instructions for connecting the 24V bus for control and power supply.

Filter, AIC, and Charging Module Connection

Diagram showing the wiring of filter, AIC, and charging modules.

Filter, AIC, Charging Module & Control DC Bus Connection

Wiring diagram for connecting filter, AIC, charging module, and control to the DC bus.

Error Chain Connection (X2 C, X2 D)

Explains the error chain connection for module communication and fault reporting.

EtherCAT System Bus (X4 B)

Details for connecting to the EtherCAT system bus for communication.

DiagnosisVisualisation Interface (X4 A)

Information on using the RS232/485 interface for diagnostics and service tools.

Control Release Connection

How to connect the control release for power module voltage supply.

Start-Up

Default Setting Configuration

Essential initial settings required before operating the drive converter.

Step-by-Step Start-up Guide (H6 AIC)

A detailed flowchart for the step-by-step start-up of the H6 AIC.