3.1.2 Mechanical ambient conditions
Storage Standard Class Notes
Vibration limits EN 60721-3-1 1M2
Vibrationamplitude1.5mm(2…9Hz)
Accelerationamplitude5m/s²(9…200Hz)
Shock limit values EN 60721-3-1 1M2 40m/s²;22ms
Transport Standard Class Notes
Vibration limits EN 60721-3-2 2M1
Vibrationamplitude3.5mm(2…9Hz)
Accelerationamplitude10m/s²(9…200Hz)
Accelerationamplitude15m/s²(200…500Hz)
Shock limit values EN 60721-3-2 2M1 100m/s²;11ms
Operation Standard Class Notes
Vibration limits
EN 60721-3-3 3M4
Vibrationamplitude3.5mm(2…9Hz)
Accelerationamplitude10m/s²(9…200Hz)
EN 61800-5-1
Vibrationamplitude0.075mm(10…57Hz)
Accelerationamplitude10m/s²(57…150Hz)
Shock limit values EN 60721-3-3 3M4 100m/s²;11ms
Pressure in the water cooler Max.operatingpressure:10bar
Table 3: Mechanical ambient conditions
3.1.3 Chemical / mechanical active substances
Storage Standard Class Notes
Contamination
Gases
EN 60721-3-1
1C2
Solids 1S2
Transport Standard Class Notes
Contamination
Gases
EN 60721-3-2
2C2
Solids 2S2
Operation Standard Class Notes
Contamination
Gases
EN 60721-3-3
3C2
Solids 3S2
Table 4: Chemical / mechanical active substances