EasyManua.ls Logo

KEB COMBIVERT F6 User Manual

KEB COMBIVERT F6
104 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
COMBIVERT F5/F6
INSTRUCTIONS FOR USE | INSTALLATION F5/F6 HOUSING P
Translation of the original manual
Document 20164377 EN 00 | Mat.No. 00F50EB-KP02

Table of Contents

Other manuals for KEB COMBIVERT F6

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT F6 and is the answer not in the manual?

KEB COMBIVERT F6 Specifications

General IconGeneral
CategoryController
SeriesCOMBIVERT F6
TypeFrequency inverter
Output Voltage0 to Input Voltage
Output Frequency0 to 400 Hz
Frequency Range0 to 400 Hz
Control MethodV/f control
Communication InterfacesCANopen, PROFIBUS
Protection ClassIP20
CoolingNatural cooling
SafetySafe Torque Off (STO) according to EN 61800-5-2
ApplicationGeneral industry, pumps, fans, conveyor systems
Protection FeaturesOvercurrent, overvoltage, undervoltage, overheating
Ambient Temperature-10°C to +40°C
Enclosure RatingIP20

Summary

Preface

Signal words and symbols

Explains safety signal words and symbols used in the documentation.

Basic Safety Instructions

1.4 Electrical connection

Details the procedures and safety measures for electrical connections.

1.5 Start-up and operation

Outlines procedures and safety precautions for starting and operating the unit.

Product Description

2.3 Product features

Lists the key characteristics and functionalities of the COMBIVERT F5/F6 series.

Technical Data

3.3 Technical data 400V class

Provides technical data for drive converters in the 400V class.

3.4 Technical data 690V class

Provides technical data for drive converters in the 690V class.

3.5 Dimensions and weights

Details the physical dimensions and weights of the units.

Mechanical Installation

4.1 Control cabinet installation

Guidelines for installing the unit within a control cabinet.

4.2 Cooling system

Information on the air and liquid cooling systems for the COMBIVERT.

Electrical Installation

6.2 Connection terminals power unit

Details the connection terminals on the power unit.

6.4 Motor connection

General instructions and precautions for connecting the motor.

Wiring Diagrams

7.2 Unit size 32...35

Illustrates mains and motor connection diagrams for unit sizes 32-35.

7.3 Unit size 36...39

Illustrates mains and motor connection diagrams for unit sizes 36-39.

Characteristics

10.1 Overload characteristic

Illustrates the overload characteristic curve of the drive converter.

10.3 Power dissipation of the 400V class at rated operation

Shows power dissipation for 400V class at rated operation by switching frequency.

Related product manuals