7.2.4 Mains connection master / slave system
-K2.3
PLC Out
ON / OFF
-K1
1
2
3
4
5
6
-U3.3
Slave
K2
K1
-U3.2
Master
K2
K1
+24V
-K2.2
-K1
13
14
ϑ
T1
T2
ϑ
T1
T2
ϑ
T1
T2
ϑ
T1
T2
ϑ
-OH1
-OH2
ϑ
-OH1
-OH2
I1
I2
I3
0V
Control
-S5.2
-S5.3
-S1.2
-S1.3
-S4.2
-S4.3
-S2
DO1
21
22
-U3.2
13
14
86.2
1
3
5
2
4
6
83.3
1
3
5
2
4
6
83.4
Legend
DO1 PLC digital output S1.2 / S1.3 Temperature switch mains choke
K1 Coupling relay S2 Emergency stop button / switch
K2.2 / K2.3 Main contactor S4.2 / S4.3 Temperature switch motor choke
U3.2 COMBIVERT master Optional
U3.3 COMBIVERT slave S5.2 / S5.3 Temperature switch braking resistor
Figure 34: Mains connection master / slave system