92
2. For triggering of the positioning process only one impuls of the proximity switch
is available. Other positions can be triggered with a reset of theshifting factor
EP.06 in set 2 and 3.
Set 0
FR.02 = 3
di.03 = 1
di.04 = 2
di.18 = 48
di.19 = 48
oP.00 = 0
oP.03 = 1
ud.12 = 1
Set 1
EP.05 = 1
EP.06 as required
EP.07 as required
oP.00 = 0
oP.03 = 0
F1
F2
Proximity switch I1
Reset after position is reached