EasyManua.ls Logo

KEB COMBIVERT F4-S/1.2

KEB COMBIVERT F4-S/1.2
96 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Annex for Software Version 1.32
92
2. For triggering of the positioning process only one impuls of the proximity switch
is available. Other positions can be triggered with a reset of theshifting factor
EP.06 in set 2 and 3.
Set 0
FR.02 = 3
di.03 = 1
di.04 = 2
di.18 = 48
di.19 = 48
oP.00 = 0
oP.03 = 1
ud.12 = 1
Set 1
EP.05 = 1
EP.06 as required
EP.07 as required
oP.00 = 0
oP.03 = 0
F1
F2
Proximity switch I1
Reset after position is reached

Related product manuals