Kelvinator Air Conditioning Installation instructions 25
Post installation checks
Items to be checked Possible malfunction
Has the unit been fixed firmly?
The unit may drop, shake or emit noise
Have you done the refrigerant leakage test? It may cause insufficient cooling (heating)
Is thermal insulation sufficient?
It may cause condensation
Is water drainage satisfactory? It may cause water leakage
Is the voltage in accordance with the rated voltage
marked on the nameplate?
It may cause electric malfunction or damage the unit
Is the electric wiring or piping connection installed
correctly and securely?
It may cause electric malfunction or damage the parts
Has the unit been securely earthed? It may cause electrical leakage
Is the power cord specified? It may cause electric malfunction or damage the parts
Is the inlet or outlet blocked?
It may cause insufficient cooling (heating)
Is the length of connection pipes and refrigerant capacity
recorded?
The refrigerant capacity is not accurate