12. Set the values as required.
13. Click the Back button.
14. Click Exit.
15. Now, log in to the iDRAC module from a web browser by entering the IP address
previously configured.
Ensure to enter https:// before the IP address.
4.2 Restore Functionality Using the iDRAC Module
The iDRAC module is an effective way of restoring functionality to units when the Solid State
Drive (SSD) needs to be replaced. The server is able to boot from an ISO uploaded to the vFlash
SD card and reinstall the firmware.
Follow the steps below to restore using the iDRAC:
1. First, create a vFlash image.
2. Then, log in to the iDRAC Web User Interface (WUI) by navigating to the IP address in a
web browser.
Ensure to enter https:// before the IP address.
3. Navigate to vFlash and select Create from Image.