4. OPERATION DISTURBANCES
4.1 THE MOST USUAL OPERATION DISTURBANCES ARE AS FOLLOWS
Arc is not ignited:
• Cable is loose or there is a bad connection.
• Electrode of torch is highly oxidized (grey). Sharpen again lengthwise. Check that post
gas time is long enough. Check ignition by using pre-gas e.g. by 4-function operation of
torch.
• There are impurities in shielding gas (moisture, air).
• Protective hose or another insulation of torch is broken and ignition spark is “escaping”
from elsewhere than from electrode of torch.
• Torch is wet.
• At low current is used too big or blunt electrode.
Gas shielding is bad (weld pool “is boiling”, electrode will be oxidized)
• There are impurities in shielding gas (moisture, air).
• There are impurities in base material (rust, base coat, grease).
• On gas nozzle or housing of tightening bushing has stuck “spatter”.
• Net of gas lens is damaged.
• There is too much draught at welding place.
• Note! With gas lens equipment you get a more balanced gas ow than with normal gas
nozzle equipment.