EasyManua.ls Logo

Kemppi MASTERTIG AC/DC 2500W - Technical Data: Mastertig AC;DC 3500 W

Kemppi MASTERTIG AC/DC 2500W
83 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Control card A003 functions / connectors
Control card A003´s functional blocks:
Secondary IGBT control power stage
Remote controller connection
AC-TIG aux. Pulse developement
OCV circuit
X1/1
Secondary IGBT control
X1/2
+ 5 V
X1/3
Secondary IGBT control
X1/4
- 15 V
X1/5
+ 15 V
X1/6
GND
X1/7
Remote controller set value
X1/8
-
X1/9
TIG/MMA selection from remote controller
X1/10
AC-TIG aux. Pulse control
X1/11
+ 24 V
X1/12
+ 15 V
X1/13
+ 15 V
X1/14
GND
X1/15
GND
X1/16
-
X2
AC-TIG aux. Pulse power supply (auxiliary coil)
X3/1,4
Secondary IGBT control
X3/3,6
Secondary IGBT control
X4
AC-TIG aux. Pulse power supply (auxiliary coil)
X5/1,3
Secondary IGBT control
X5/3,5
Secondary IGBT control
X7
Protective earth
X8/1
TIG/MMA selection from remote controller
X8/2
Remote controller potentiometer voltage reference
X8/3
Remote controller potentiometer "slide"
X8/4
Remote controller potentiometer ground
X10
AC-TIG aux. Pulse / OCV circuit DC +
X11
OCV circuit DC -
X12
Main transformer secondary mid-points
30

Other manuals for Kemppi MASTERTIG AC/DC 2500W