Sigma XT
Extinguishant Control Panel
(K11031M2, K11031F2)
Operation and Maintenance Manual
Man-1088 Issue 26 February 2015

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Kentec Electronics Sigma XT K11031M2 and is the answer not in the manual?

Summary

Safety and Mounting

Safety

Essential safety guidelines for installation and use, emphasizing compliance with regulations and proper handling.

Mounting

Instructions for physically mounting the control panel on a dry, flat surface at eye height.

Technical Specification

Control Panel Fascia

Connecting to the Circuit Board

Detection Zone Wiring

Connection to Extinguishant Output

Solenoid Wiring

Specific wiring requirements for solenoids, including resistance and suppression diodes.

Igniting Actuator Wiring

Wiring details for igniting actuators, including series connection and resistors.

Setting up Extinguishant Monitoring Circuit

Procedure for setting up the extinguishant monitoring circuit, including adjustment.

Connection and Configuration of Status Units and Ancillary Boards

Adding New Status Units;Ancillary Boards

Procedure for adding new status units and ancillary boards to the system.

Removing Status Units;Ancillary Boards

Procedure for removing status units and ancillary boards from the system.

Panel Operation

Single Zone Fire Condition

How the panel indicates and responds to a single zone fire condition.

Double Zone Fire Condition

Details on the panel's response to a second fire condition, leading to extinguishant release.

Manual Release

How to activate manual release and its operational response.

Silence;Sound Alarms

Procedure for silencing or sounding alarms using the panel buttons.

Zone Fault

How zone faults are indicated on the panel.

Sounder Fault

How sounder circuit faults are indicated on the panel.

Power Fault

How power supply failures are indicated on the panel.

System Fault

Indicates a system fault, often due to configuration issues.

General Fault

General fault indicator that illuminates under various fault conditions.

Hold Condition

Describes the hold condition and its effect on the extinguishant release sequence.

Released Condition

Indicates when the extinguishant has been released based on pressure switch input.

Low Pressure Switch

Indicates low pressure in the extinguishant cylinder, potentially a fault.

Disablements

Disable Zones

How to disable individual zones, affecting fire/fault reporting.

Access Level 2 Configuration Options

Access Level 3 Configuration Options

Internal Controls

Commissioning

Requirements for storing configuration changes during commissioning.

Internal Indications - Troubleshooting

Power Supply

Maintenance

Commissioning Instructions