Kentec Electronics Taktis User Manual

Kentec Electronics Taktis
17 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image


!"#$$$$%&'$
'(
!&)*

Other manuals for Kentec Electronics Taktis

Question and Answer IconNeed help?

Do you have a question about the Kentec Electronics Taktis and is the answer not in the manual?

Kentec Electronics Taktis Specifications

General IconGeneral
BrandKentec Electronics
ModelTaktis
CategoryControl Panel
LanguageEnglish

Summary

Identifying Status Information

Fire System Normal

Describes the normal operating state of the fire control panel without active events.

Left LED Indicators

Fire LED

Indicates a fire alarm or fire drill condition, with intermittent buzzer and output relay activation.

General Fault LED

Flashes when fault conditions exist, accompanied by other fault LEDs.

System Fault LED

Indicates internal circuit problems with continuous buzzer and flashing LED.

Power Fault LED

Indicates a fault condition on the main or backup power supplies.

General Disablement LED

Indicates parts of the system have been manually disabled and are inactive.

Pre-Alarm LED

Signals detectors near alarm limits, indicating an imminent fire alarm condition.

Right LED Indicators

Fire Routing On LED

Signals transmission to remote equipment or confirmation signals received.

Fire Routing Fault/Disabled LED

Indicates disabled remote transmission or fault in the transmission path.

Test Mode On LED

Indicates one or more zones have been selected for Test Mode.

Delays Active LED

Shows sounders are delayed during a fire condition, with flashing LED and buzzer.

Sounder Fault/Disabled LED

Lights for disabled sounders/circuits, flashes for sounder faults.

Power On LED

Indicates power is being supplied to the fire control panel.

Performing Commands

User Access Levels

Describes different levels of user access for panel operations and available commands.

Example Fire Condition

LED Indicators in Fire Condition

Details illuminated LED indicators for Zone 12, Fire Routing On, and Power On during a fire.

Login

Login Window

Displays the interface for entering credentials to access panel controls.

Silence Alarms

Silence Alarms Command

Explains the command to quiet internal buzzer and network sounders.

Re-sound Alarms

Re-sound Alarms Command

Explains the command to re-sound the internal buzzer and external sounders.

Reset System

Reset System Command

Describes clearing latching inputs and restoring the panel to normal.

Logout

Logout Procedure

Details pressing the Logout button to exit User Level 2.

Navigating the Menu

Menu Path for User Level 2

Illustrates the menu path for navigating User Level 2 of the fire control panel.

Notifying the Emergency Contact

Emergency Contact Details

Provides fields to record emergency contact information for assistance.