EasyManua.ls Logo

Kenwood X-E5 - Page 29

Kenwood X-E5
54 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
X-E5
ADJUSTMENT
Operation
e
If
the
power
is
turned
on
with
the
test
pin
jumper
shorted,
the
A
PB
Lch
data
are
set.
At
this
time,
the
value
currently
written
in
the
E?PROM
is
read
as
each
adjustment
data.
The
ad-
justment
OK/ERR
condition
is
also
read
(only
when
the
normal
data
are
written).
Besides,
all
the
adjustment
finish
conditions
are
turned
off
and
all
the
backup
check
data
are
broken.
if
the
adjustment
data
for
an
item
is
not
written,
the
center
value
is
read.
e
Select
an
item
to
be
adjusted
with
the
[DOLBY]
key,
and
heighten
or
lower
the
adjustment
value
with
the
[SKIP
UP/SKIP
DOWN]
keys.
If
in
the
unit
mode,
the
adjustment
value
of
the
cur-
rently
adjusted
item
is
output
in
series.
If
in
the
system
mode,
the
adjustment
value
of
the
currently
adjusted
item
is
indicated.
Explanation
of
keys
e
[N/DUBB]
key
:
Deletion
of
each
adjustment
item
Used
to
initialize
only
the
adjustment
value
of
the
cur-
rently
adjusted
item.
A,
B
PB
value>30
B
REC
EQ
value->15
B
BIAS
value>40
Unit
mode
:
Short
No.
3
and
No.
7
of
CN9
to
each
other.
*
[H/DUBB]
key
:
Writing
of
all
adjustment
items
Used
to
transfer
all
the
currently
adjusted
data
to
the
E?PROM
write
in
it,
so
that
they
can
be
backed
up.
Also
used
to
complete
the
adjustment
in
each
mode
and
back
it
up.
If
this
key
is
pressed
during
the
manual
adjustment,
when
the
machine
is
turned
on
in
the
normal
mode
or
test
mode
next
time,
the
adjustment
data
are
read
out
of
the
E7PROM.
Unit
mode
:
Short
No.
4
and
No.
7
of
CN9
to
each
other.
After
the
adjustment,
if
the
manual
adjustment
is
re-
set
without
pressing
this
key,
when
the
machine
is
turned
on
in
the
normal
mode
or
test
mode
next
time,
the
initial
values
are
read
since
the
backup
check
data
have
not
been
written.
*
®
[DOLBY]
key
:
Cyclic
change
of
adjustment
item
Used
to
change
the
currently
adjusted
item
cyclically.
*
Unit
mode
:
Short
No.
2
and
No.
7
of
CN9
to
each
other.
IA
PB
Lch]IA
PB
Reh]
[B
PB
Lch][B
PB
Reh]>
€-[B
BIAS
Rch]CIB
BIAS
Lch]{B
REC
Reh}<I[B
REC
Leh]e~
¢
[SKIP
UP/DOWN]
key
:
Heightening
and
lowering
of
adjustment
value
Used
to
heighten
and
lower
the
adjustment
value
of
the
currently
adjusted
item.
UP:
(Example
:
63
step
>:
15
step
>-..-+
0
step)
DOWN
:
(Example
:
0
step
>--->
15
step
---»
63
step)
Each
time
the
value
is
changed,
the
adjustment
data
conformed
to
the
current
operation
of
the
mecha-
nism
are
transferred
to
the
system
IC,
then
the
serial
code
is
output
or
indicated.
Adjustment
range
PB
:
0~63
step
REC
EQ
:
0~31
step
BIAS
:
20~60
step
*
Unit
mode
UP
:
Short
No.
4
and
No.
6
of
CN9
to
each
other.
DOWN
:
Short
No.
3
and
No.
6
of
CN9
to
each
other.
¢
[CCRS]
key
Used
to
reset
the
manual
adjustment
mode.
*
Unit
mode
:
Short
No.
1
and
No.
7
of
CN9
to
each
other.
,
e
Other
keys
Used
for
the
ordinary
operation.
29