126
770/GS/GJ-BA-defsi-0023
6.7 Interface Parameter Settings
Baud Rate Code
Changes
Utilities
150 Baud 5 1 1 Data Output Parameter Changes
300 Baud 5 1 2 Print on request
600 Baud 5 1 3 without stability 6 1 1
1,200 Baud 5 1 4 * Print on request
2,400 Baud 5 1 5 after stability 6 1 2 *
4,800 Baud 5 1 6 Print on request
9,600 Baud 5 1 7 at stability 6 1 3
19,200 Baud 5 1 8 Auto print
without stability 6 1 4
Parity Code
Changes
Auto print
Mark Parity 5 2 1 at stability 6 1 5
Space Parity 5 2 2
Odd Parity 5 2 3 * Print Interval after Code Changes
Even Parity 5 2 4 1 display update 6 3 1 *
2 display updates 6 3 2
Number of Stop Bits
Changes
1 stop bit 5 3 1 * Data ID code Changes
2 stop bits 5 3 2 Without 7 2 1 *
With 7 2 2
Handshake
Mode
Code
Changes
Software
handshake
5 4 1
Hardware -
handshake with
2 characters
after CTS
5 4 2
*
Hardware-
handshake with
1 character
after CTS
5 4 3
* = factory setting