EasyManua.ls Logo

KERN 572 User Manual

KERN 572
66 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
KERN & Sohn GmbH
www.kern-sohn.com
Ziegelei 1
72336 Balingen-Frommern
Germany
+0049-[0]7433-9933-0
+0049-[0]7433-9933-149
info@kern-sohn.com
Operating instructions
Precision balance
KERN 572
Type T572-A
Version 1.1
2023-03
GB

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the KERN 572 and is the answer not in the manual?

KERN 572 Specifications

General IconGeneral
Weighing capacity600 g
CalibrationExternal
DisplayLCD
CategoryScales
MaterialStainless steel
Weighing unitsg, oz, ozt, dwt, ct, gn, tl
Power supplyAC Adapter

Summary

Technical data

Basic Information (General)

4.1 Proper use

Explains the intended purpose and correct way to use the balance for accurate weighing.

Basic Safety Precautions

5.1 Pay attention to the instructions in the Operation Manual

Emphasizes the importance of carefully reading the operation manual before setup and use.

5.1 Personnel training

States that only trained staff are permitted to operate and maintain the appliance.

Unpacking, Installation and Commissioning

7.4 Mains connection

Provides instructions and important safety notes for connecting the balance to the mains power supply.

7.8 Adjustment

Explains the importance and process of adjusting the balance for accurate weighing based on location.

7.8.1 External adjustment < CALEHE >

Step-by-step guide for performing external calibration using a specific, pre-defined adjustment weight.

7.8.2 External adjustment with user-defined adjustment weight < cAL Eud >

Instructions for external calibration when using a user-specified adjustment weight.

Basic Operation

8.1 Turn on/off

Provides clear instructions for powering the balance on and off safely.

8.2 Simple weighing

A step-by-step guide for performing a basic weighing operation.

8.3 Zeroing

Explains how to reset the balance to zero before starting a weighing.

8.4 Taring

Details the process of taring to measure the net weight of goods.

Application <Weighing>

Application <Counting>

Application < Checkweighing >

Instant help for troubleshooting

The weight display does not glow.

Addresses issues where the balance display is not illuminated, listing possible causes.

The displayed weight is permanently changing

Explains causes for an unstable or fluctuating weight reading on the display.

The weighing result is obviously incorrect

Lists common reasons for inaccurate weighing results and potential solutions.

Error messages

JLNE: Zero setting range exceeded

Explanation for the "Zero setting range exceeded" error message.

under2: Zero setting range not achieved

Explanation for the "Zero setting range not achieved" error.

SEAG: Load instable

Explanation for the "Load unstable" error message.

BronG: Adjustment error

Explanation for the "Adjustment error" message.

L---7: Underload

Explanation for the "Underload" error message.

LO BAE: Overload

Explanation for the "Overload" error message.

LO BAE: Capacity of batteries / rechargeable batteries exhausted

Explanation for the error indicating depleted battery capacity.

Related product manuals