EN
52
Belowinstructionsareintendedforqualifiedtechnicianinstallingthisappliance.Theseinstructions
areintendedtoensurethattheinstallationoperationsandthemaintenanceofthedevicearecarriedout
inthemostefficientwaypossible.
• Beforeinstallingmake sure thatthelocaldistribution conditions(gastypeand pressure)
andsettingofthedeviceareappropriate.
• Thesettingconditionsforthisdevicearestatedonaplaterate.
• Thisapplianceisnotmeanttobeconnectedtoexhaustpipes.Shouldbeinstalledandconnected
accordingthecurrentregulations.Inparticularshouldbetakenintoconsiderationadequate
requirementswhichaplliestoventilation.
• Thekitchenroomshouldbedryandairy.Alsoshouldhaveworkingventilation,whichmeets
therequiarementsofcurrentregulations.Thelegalbasisonwhichweassessthesustability
oftheroomforinstallingagascookerinit,istheOrdinanceofMinisterofInfrastructure
from April 12, 2002 regarding technical conditions, which buildings and their location
shouldanswer.
• Theroomshouldhaveinstalledventilationsystem,whichexhaustthefumesduringburning.
Thisventilationshouldconsistofventorthekitchenhood.Thehoodsshouldbeinstalled
accordingtothetipsgiveninmanualinstructions.Thecookersettingshoudbeensureeasy
accesstoallsteeringcomponents.
• Theroomshouldalsoensureconstatairsupply,whichisnecessarytoproperburninggas.
Airsupplyshoundbenotlessthan2m
3
/hon1kWburnerspower.Theairmaybysupplied
asaresultofdirectflowfrominsidethroughachannelwithcross-sectionodatleast100cm
2
,
orindirectlyfromadjacentroomsthatareequippedwithventilationductscomingouttothe
outside.
• LPGisheavierthanairandthereforetendstoaccumulateatlowerlevels.Therooms,inwhich
gascylindershavebeeninstalled,shouldbeequippedwithventilationductsledoutformthe
roomtooutside,allowinggastoescapeintheeventof aleak.Forthesamereason,gas
cylinders,bothemptyandpartiallyfilled,shouldnotbeinstalledorstoredinroomslocated
belowtheearth’sSurface(e.g.basements).Thecylindersmustnottobetooclosetosources
ofheat(stoves,fireplaces,ovens,etc.)thatcouldincreasethe
temperatureinsidethecylinderabove50ºC.
• ClassofapplianceaccordingtoEN30-1-1:class2-subclassI.