Thestabilizinglockismountedtopreventtheappliancefromtipping.Dueto
installedlock,childshouldnotbeabletoclimbontheovendoorandcause
thetippingodappliance.
Thecookerwithheight850mm:
A=60mm
B=103mm
Thecookerwithheight900mm:
A=104mm
B=147mm



Thecookershouldbeconnectedtogasinstallation,tothetypeofgastowhichappliancewasfabrically
adapted.Informationaboutthetypeofgasissuitableforthisapplianceislocatedonratingplate.The
cookershouldbemountedbyaqualificatedtechnician,andonlyheisabletoadjustthegascookerto
differenttypeofgas


Haveentitlementtoconductgasinstallment.
Getfimiliarwithinformationsstatedonratingplateaboutthetypeofgasissuitableforthis
appliance.Thisspecifictaionshouldbecomparedwithinformationsprovidedbythelocal
distributorofgas.
Checkout:
-Ventilationefficiency.
-Gasconnectionsforleaks.
-Efficiencyofallfunctionalelementscooker.
-Ifthepowersupplysystemisadjusttoworkwithaprotectiveconductor(zero).
Forproperworkingofspark igniterandgasoutflowprotection, adjustthesettingofgas
knobswithwasherssupplied:
-Checktheworkingofsparkigniterandgasoutflowprotection.
-Inthecaseofmalfunction,removetheknob,makeadjustmentbyinsertingthewasher(s)onthe
valvestem.
-Aftertheadjusting,securethesystemwithclampingwasherandinstalltheknob.
Givetheusersthegas cookerconnectioncertificate andfamiliarizethemwithusage the
appliance.