For devices with K connectors (2.92 mm), continued
Mechanical calibration kits, continued
Electronic calibration kits
N4692A Microwave ECal: 10 MHz to 40 GHz, 2-ports.
Includes:
Option M0F module with: N4692-60001 2.92 mm (f) to
2.92 mm (m) ECal module
Option 00M module with: N4692-60002 2.92 mm (m) to
2.92 mm (m) ECal module
Option 00F module with: N4692-60003 2.92 mm (f) to
2.92 mm (f) ECal module
Option 00A adds:
N4692-60021 2.92 mm (m) to 2.92 mm (m) adapter
N4692-60022 2.92 mm (f) to 2.92 mm (f) adapter
Cables
Note: Keysight offers the following 2.4 mm test port cables. Adapters will be
necessary when using these cables for 2.92 mm measurements.
85133C
1
single, semi-rigid: 2.4 mm (f) to PSC-2.4 mm (f),
81 cm, 32 inches
85133D
1
set, semi-rigid:
One 2.4 mm (f) to 2.4 mm (m), 53 cm, 21 inches,
p/n 85133-60001
One 2.4 mm (f) to 2.4 mm (f), 53 cm, 21 inches,
p/n 85133-60002
85133E
1
single, flexible: 2.4 mm (f) to PSC-2.4 mm (f), 97 cm,
38 inches
85133F
1
set, flexible:
One 2.4 mm (f) to 2.4 mm (f), 63 cm, 25 inches,
p/n 85133-60016
One 2.4 mm (f) to 2.4 mm (m), 63 cm, 25 inches,
p/n 85133-60017
85133H
1
Single, flexible: 2.4 mm (f) to 2.4 mm (m),
63 cm, 25 inches
N4421AK20 Single, flexible: 2.4 mm (f) to 2.4 mm (m),
91.4 cm, 36 inches
Adapters
11904A 2.4 mm (m) to 2.92 mm (m)
11904B 2.4 mm (f) to 2.92 mm (f)
11904C 2.4 mm (m) to 2.92 mm (f)
11904D 2.4 mm (f) to 2.92 mm (m)
11904S 2.4 mm to 2.92 mm
Adapter set, contains 4 matched adapters
1. Special rugged female connector specifically for connecting to the
network analyzer test port, but does not mate with a standard male
connector.
For devices with 3.5 mm, SMA, or
2.92 mm connectors
CalPod calibration refresh modules
CalPod calibration refresh modules allow in-situ calibration
refreshes to be performed at the push of a button without remov-
ing the DUT or connecting calibration standards. They're useful
for removing environmental effects such as cable movement,
thermal effects of cables, connectors, and adapters, as well as
connector and switch matrix repeatability errors, or whenever it
is desirable to ensure a current and valid calibration is present.
The modules are especially useful in thermal or thermal-vacuum
chamber testing.
85530B 20 GHz Ambient temperature CalPod calibration
refresh module
85531B 20 GHz Temperature-compensated CalPod
calibration refresh module
85532B 20 GHz Thermal-vacuum compatible CalPod
calibration refresh module
85540A 40 GHz Ambient temperature CalPod calibration
refresh module
85541A 40 GHz Temperature-compensated CalPod
calibration refresh module
85542A 40 GHz Thermal-vacuum compatible CalPod
calibration refresh module
85523B CalPod controller; Provides control for up to four
CalPods
85556A CalPod drive cable splitter; Allows control for up to
12 CalPods
85554A CalPod drive cable extension; 10 meter extension
cable; cascadable.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies N5224A and is the answer not in the manual?

Keysight Technologies N5224A Specifications

General IconGeneral
BrandKeysight Technologies
ModelN5224A
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals