PNA Family Network Analyzer Upgrade Kits (continued)
Application options
Upgrade kits are available to add options after initial purchase. To upgrade the PNA-X/PNA/PNA-L, order the corresponding
item number. The model and serial numbers of the instrument to be retrofitted are required as part of the order.
1. For measuring frequency converters, Option 082 or 083 is required.
2. Requires configurable test set for signal conditioning of noise figure measurements using standard receivers. Therefore it is not available with N522xA-200, -210,
-400 and -410.
3. Upgrading N5244A units with noise figure hardware requires serial-number prefixes of 5204 or higher, and upgrading N5245A units requires serial-number prefixes of
5205 or higher. For these two models, units with lower serial-number prefixes can be traded in for credit towards a new unit with the noise figure hardware.
4. Two-tone signal must be routed to R1 receiver after an external combiner; therefore it is not available with N522xA-200, -210, -400 and -410.
5. When used with an external signal generator, configurable test set is required to access a receiver. Therefore it is not available with N522xA-200 and -210.
6. To connect a multiport test set, configurable test set is required. Therefore it is not available with N522xA-200, -210, -400, -410, and N523xA-200, and -400.
7. The Windows 7 upgrade kit for PNAs containing CPU version 6 is model N8983A. This upgrade kit contains a new solid state drive with all of the necessary software
installed. For units with older CPUs, order the N8984A with Option PC7. This upgrade kit contains a new solid state drive and a version 7 CPU. For adding Option 090
to units with DSP version 4, add Option SP5 to the N8983A or N8984A order to get the DSP version 5.
8. A configurable test set is required for VMC measurements (to connect a reference mixer) or for SMC+Phase measurements using the comb-generator-based calibration.
When ordered with N522xA-200, -210, -400 and -410, Option 083 adds phase and delay measurements only by using SMC+Phase with a calibration mixer.
9. Optional receiver attenuators are recommended to avoid receiver compression for large-signal measurements.
10. Option 093 is a subset of Option 094; therefore they cannot be ordered together.
11. Some parameters are is restricted to 50 GHz.
Description Required Option
For PNA-X
Series
For PNA
Series
For PNA-L
Series
User
Installable
Measurement applications
Automatic xture removal Windows 7 OS
7
. N524xAU-007 N522xAU-007 N523xAU-007 Yes
Time-domain measurements N524xAU-010 N522xAU-010 N523xAU-010 Yes
Noise gure measurements using standard receivers Option 080
1,2
N524xAU-028 N522xAU-028 n/a Yes
Fully-corrected noise gure measurements
for PNA-X, 2-ports
Option 080 and for N5241/42/49A, one of Op-
tions 219, 224 or H85
1
.
For N5244/45/47A, 080 and 224
N524xAU-924
3
n/a n/a No
Fully-corrected noise gure measurements
for PNA-X, 4-ports
Option 080 and for N5241/42/49A, one of Op-
tions 419, 423 or H85
1
.
For N5244/45/47A, 080 and 423
N524xAU-929
3
n/a n/a No
Frequency offset N524xAU-080 N522xAU-080 N523xAU-080 Yes
Scalar-calibrated converter measurements Option 080 N524xAU-082 N522xAU-082 N523xAU-082 Yes
Vector- and scalar-calibrated converter measurements
Option 080
8
N524xAU-083 N522xAU-083 n/a Yes
Embedded LO measurements Option 082 or 083 N524xAU-084 N522xAU-084 n/a Yes
Gain compression application See Footnote 1 N524xAU-086 N522xAU-086 n/a Yes
Intermodulation distortion application Option 080
1,4
N524xAU-087 N522xAU-087 n/a Yes
Source phase control See Footnote 5 N524xAU-088 N522xAU-088 n/a Yes
Differential and I/Q devices application Option 080 and 400, 401, 410, 417, or 419, and
Windows 7 OS
7
N524xAU-089 N522xAU-089 n/a Yes
Spectrum analyzer Option 080, Windows 7 OS, and
DSP version 5
7, 9
N524xAU-090 N522xAU-090 523xAU-090 Yes
Extended spectrum analyzer to 110 GHz
10
Option 090. Not available with N5241/49A or
N5221A
N524xAU-093 N522xAU-093 n/a Yes
Extended spectrum analyzer above 110 GHz
10
Option 090. Not available with N5241/49A or
N5221A
N524xAU-094 N522xAU-094 n/a Yes
Active hot parameters (export-controlled version) Option 080 and 400, 400/419, or 400/419/423 N524xAU-110 n/a n/a Yes
Active hot parameters
11
Option 080 and 400, 400/419, or 400/419/423 N524xAU-111 n/a n/a Yes
Integrated true-mode stimulus application Option 400, 401, 417, 419, or 423 N524xAU-460 N522xAU-460 n/a Yes
N-port capabilities See Footnote 6 N524xAU-551 N522xAU-551 N523xAU-551 Yes

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies N5224A and is the answer not in the manual?

Keysight Technologies N5224A Specifications

General IconGeneral
BrandKeysight Technologies
ModelN5224A
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals