22 | Keysight | PNA Family Microwave Network Analyzers - Congurations Guide
PNA Family Network Analyzer Upgrade Kits (continued)
Application options
Upgrade kits are available to add options after initial purchase. To upgrade the PNA-X/PNA/PNA-L, order the corresponding
item number. The model and serial numbers of the instrument to be retrotted are required as part of the order.
1. For measuring frequency converters, Option 082 or 083 is required.
2. Requires congurable test set for signal conditioning of noise gure measurements using standard receivers. Therefore it is not available with N522xA-200, -210,
-400 and -410.
3. Upgrading N5244A units with noise gure hardware requires serial-number prexes of 5204 or higher, and upgrading N5245A units requires serial-number prexes of
5205 or higher. For these two models, units with lower serial-number prexes can be traded in for credit towards a new unit with the noise gure hardware.
4. Two-tone signal must be routed to R1 receiver after an external combiner; therefore it is not available with N522xA-200, -210, -400 and -410.
5. When used with an external signal generator, congurable test set is required to access a receiver. Therefore it is not available with N522xA-200 and -210.
6. To connect a multiport test set, congurable test set is required. Therefore it is not available with N522xA-200, -210, -400, -410, and N523xA-200, and -400.
7. The Windows 7 upgrade kit is model N8983A. This upgrade kit contains a new disk drive and requires an i7 or Celeron CPU. For units with older CPUs, order Option
PC6 for a new i7 CPU. When adding Option 090 on units with an older CPU, order Options PC6 and SP5.
8. A congurable test set is required for VMC measurements (to connect a reference mixer) or for SMC+Phase measurements using the comb-generator-based calibra-
tion. When ordered with N522xA-200, -210, -400 and -410, Option 083 adds phase and delay measurements only by using SMC+Phase with a calibration mixer.
9. Optional receiver attenuators are recommended to avoid receiver compression for large-scale measurements.
Description Required Option
For PNA-X
Series
For PNA
Series
For PNA-L
Series
User
Installable
Measurement applications
Automatic xture removal Windows 7 OS
7
. N524xAU-007 N522xAU-007 N523xAU-007 Yes
Time-domain measurements N524xAU-010 N522xAU-010 N523xAU-010 Yes
Noise gure measurements using standard receivers Option 080
1,2
N524xAU-028 N522xAU-028 n/a Yes
Fully-corrected noise gure measurements
for PNA-X, 2-ports
Option 080 and for N5241/42/49A, one of Op-
tions 219, 224 or H85
1
.
For N5244/45/47A, 080 and 224
N524xAU-924
3
n/a n/a No
Fully-corrected noise gure measurements
for PNA-X, 4-ports
Option 080 and for N5241/42/49A, one of Op-
tions 419, 423 or H85
1
.
For N5244/45/47A, 080 and 423
N524xAU-929
3
n/a n/a No
Frequency offset N524xAU-080 N522xAU-080 N523xAU-080 Yes
Scalar-calibrated converter measurements Option 080 N524xAU-082 N522xAU-082 N523xAU-082 Yes
Vector- and scalar-calibrated converter measurements
Option 080
8
N524xAU-083 N522xAU-083 n/a Yes
Embedded LO measurements Option 082 or 083 N524xAU-084 N522xAU-084 n/a Yes
Gain compression application See Footnote 1 N524xAU-086 N522xAU-086 n/a Yes
Intermodulation distortion application Option 080
1,4
N524xAU-087 N522xAU-087 n/a Yes
Source phase control See Footnote 5 N524xAU-088 N522xAU-088 n/a Yes
Differential and I/Q devices application Option 080 and 400, 401, 410, 417, or 419, and
Windows 7 OS
7
N524xAU-089 N522xAU-089 n/a Yes
Spectrum analyzer Option 080, Windows 7 OS, and
DSP version 5
7, 9
N524xAU-090 N522xAU-090 n/a Yes
Integrated true-mode stimulus application Option 400, 401, 417, 419, or 423 N524xAU-460 N522xAU-460 n/a Yes
N-port capabilities See Footnote 6 N524xAU-551 N522xAU-551 N523xAU-551 Yes
Pulse, antenna, mm-wave
Pulsed-RF measurements Option 025
1
N524xAU-008 N522xAU-008 n/a Yes
Add IF inputs N524xAU-020 N522xAU-020 n/a Yes
Add pulse modulator to internal 1st source N524xAU-021 N522xAU-021 n/a Yes
Add pulse modulator to internal 2nd source Option 224, 400, 401, 417, 419, or 423 N524xAU-022 N522xAU-022 n/a Yes
Add four internal pulse generators N524xAU-025 N522xAU-025 n/a Yes
Fast CW sweep N524xAU-118 N522xAU-118 n/a Yes