29 | Keysight | PNA Family Microwave Network Analyzers - Congurations Guide
– 85133F
1
set, exible:
One 2.4 mm (f) to 2.4 mm (f), 63 cm, 25 inches,
p/n 85133-60016
One 2.4 mm (f) to 2.4 mm (m), 63 cm, 25 inches,
p/n 85133-60017
– 85133H
1
Single, exible: 2.4 mm (f) to 2.4 mm (m), 63
cm, 25 inches
– N4421AK20 Single, exible: 2.4 mm (f) to 2.4 mm (m),
91.4 cm, 36 inches
Adapter set
– 85130E 2.4 mm
1
to 7 mm
– 85130F 2.4 mm
1
to 3.5 mm
– 85130G 2.4 mm
1
to 2.4 mm
For devices with K connectors (2.92 mm)
Mechanical calibration kits
85056KE01 DC to 40 GHz
For use with user supplied 2.9 mm test port cables.
2.92 mm (K connector) calibration kit with xed and sliding
loads. The Keysight 85056KE01 calibration kit is an ordering
convenience to allow the pass through ordering from
Keysight for the Maury 8770C47 calibration kit.
85056KE02 DC to 40 GHz
For use with user supplied 2.92 mm test ports cables.
2.92 mm (K connector) calibration kit with xed loads only.
The Keysight 85056KE02 calibration kit is an ordering
convenience to allow the pass through ordering from
Keysight for the Maury 8770D47 calibration kit.
The 85056KE01 and 85056KE02 contains one NMD
2.4 mm
2
(f) to 2.92 mm (f) and one NMD 2.4 mm
2
(f) to 2.92
mm (m) test port adapter to adapt the 2.4 mm test ports of
the PNA to 2.92 mm. It also supplies 2.92 mm to 2.92 mm
in-series adapters (3 adapters) and a PNA Cal Coefcients
on a USB stick. Users must supply their own 2.92 mm or
K-connector test port cables. Also included is a 2.92 mm
torque wrench.
Maury Microwave Terms and Conditions for Warranty and
Return apply. Maury Microwave Corp. calibration kits are to
be returned directly to Maury Microwave for service, repair,
or calibration issues and not to Keysight Technologies. For
additional information go to www.maurymicrowave.com.
Keysight Technologies does not guarantee the performance
of the Maury calibration kits or the system performance
when connected to Keysight Microwave PNA Series network
analyzers.
For devices with 2.4 mm connectors
Mechanical calibration kit
85056A standard: DC to 50 GHz. Includes:
– 00901-60003 2.4 mm (m) xed broadband load
– 00902-60004 2.4 mm (f) xed broadband load
– 00915-60003 2.4 mm (m) sliding load
– 00915-60004 2.4 mm (f) sliding load
– 85056-60005 2.4 mm (m) to 2.4 mm (m) adapter
– 85056-60006 2.4 mm (f) to 2.4 mm (f) adapter
– 85056-60007 2.4 mm (m) to 2.4 mm (f) adapter
– 85056-60020 2.4 mm (m) short
– 85056-60021 2.4 mm (f) short
– 85056-60022 2.4 mm (m) open
– 85056-60023 2.4 mm (f) open
85056D economy: DC to 50 GHz. Includes:
– 00901-60003 2.4 mm (m) xed broadband load
– 00902-60004 2.4 mm (f) xed broadband load
– 85056-60005 2.4 mm (m) to 2.4 mm (m) adapter
– 85056-60006 2.4 mm (f) to 2.4 mm (f) adapter
– 85056-60007 2.4 mm (m) to 2.4 mm (f) adapter
– 85056-60020 2.4 mm (m) short
– 85056-60021 2.4 mm (f) short
– 85056-60022 2.4 mm (m) open
– 85056-60023 2.4 mm (f) open
Electronic calibration kits
N4693A Microwave ECal: 10 MHz to 50 GHz, 2-ports.
Includes:
– Option M0F module with:
N4693-60001 2.4 mm (f) to 2.4 mm (m) ECal module
– Option 00M module with:
N4693-60002 2.4 mm (m) to 2.4 mm (m) ECal module
– Option 00F module with:
N4693-60003 2.4 mm (f) to 2.4 mm (f) ECal module
– Option 00A adds:
– 85056-60005 2.4 mm (m) to 2.4 mm (m) adapter
– 85056-60006 2.4 mm (f) to 2.4 mm (f) adapter
Cables
Note: Keysight offers the following 2.4 mm test port cables.
Adapters will be necessary when using these cables for 2.92 mm
measurements.
– 85133C
1
single, semi-rigid:
2.4 mm (f) to PSC-2.4 mm (f), 81 cm, 32 inches
– 85133D
1
set, semi-rigid:
One 2.4 mm (f) to 2.4 mm (m), 53 cm, 21 inches,
p/n 85133-60001
One 2.4 mm (f) to 2.4 mm (f), 53 cm, 21 inches,
p/n 85133-60002
– 85133E
1
single, exible:
2.4 mm (f) to PSC-2.4 mm (f), 97 cm, 38 inches
1. Special rugged female connector specically for connecting to the network analyzer test port, but does not mate with a standard male connector.
2. Special rugged female connector specically for connecting to the network analyzer test port, but does not mate with standard 2.4 mm male connector