Keysight N6705C Specifications

General IconGeneral
ModelN6705C
CategoryDC Power Analyzer
Number of Slots4
Maximum DC Power per Module300 W
Data LoggingYes
Data Logging RateUp to 50, 000 readings/second
TypeModular
Voltage RangeUp to 60 V
Current RangeVaries by module. Up to 50 A
Power per OutputUp to 300 W
Voltage ResolutionUp to 100 µV
Voltage Programming Accuracy0.03% + 10 mV
Voltage Measurement Accuracy0.03% + 10 mV
Ripple and Noise (20 Hz to 20 MHz)2 mVpp (typical)
Measurement CapabilitiesVoltage, Current, Power
DisplayColor
InterfaceGPIB, LAN, USB
ConnectivityEthernet, USB

Summary

Legal and Safety Information

Safety Notices

General safety precautions for operating the instrument, including warnings for environmental conditions and grounding.

1 Quick Reference

Introduction to the Instrument

Overview of the N6705 DC Power Analyzer's features, functions, and views.

Command Quick Reference

A reference of SCPI commands for controlling instrument functions like abort, calibrate, and display.

2 Installation

Preliminary Information

Information on checking supplied items, inspecting the unit, reviewing safety, and observing environmental conditions.

Installing the Power Analyzer

Procedures for installing the power analyzer, including power module installation, high-current connections, and bench/rack mounting.

Connecting the Power Cord

Instructions for connecting the power cord, including safety warnings for fire and shock hazards.

Connecting the Outputs

Details on connecting outputs using binding posts, wire sizing, and specific wiring for N678xA SMU and multiple loads.

3 Using the Source Functions

Turning the Unit On

Instructions for powering on the instrument, including initialization time and front panel controls.

Using the Power Supply

Guides on controlling outputs, setting voltage and current, enabling outputs, and viewing output voltage and current.

Generating Arbitrary Waveforms

Explains how the arbitrary waveform generator function modulates output, defines waveforms with points, and combines Arbs into sequences.

Using the Protection Functions

Describes independent protection functions like OV, OC, OT, OSC, PROT, and INH for each output.

4 Using the Measurement Functions

5 Using the System Functions

6 Advanced Source, Measurement, and Control

7 SCPI Programming Reference

8 Verification and Calibration

Performance Verification

Verifies normal operation and published specifications using performance and calibration tests.

Module Calibration

Details power module calibration procedures, including voltage, current, resistance, and downprogrammer calibration.

9 Service and Maintenance

Firmware Update

Guides on updating instrument firmware via www.keysight.com/find/N6705firmware, including download and utility steps.

Troubleshooting

Provides preliminary checkout, overall troubleshooting steps, and specific troubleshooting for bias board, backplane, and calibration issues.