Function Command
[SOURce:]FUNCtion CURRent|VOLTage, (@<chanlist>)
[SOURce:]FUNCtion? (@<chanlist>)
Sets the output regulation - voltage priority or current priority.
In voltage priority mode the output is controlled by a bi-polar constant voltage feedback loop, which
maintains the output voltage at its positive or negative programmed setting. In current priority mode
the output is controlled by a bi-polar constant current feedback loop, which maintains the output
sourcing or sinking current at its programmed setting. Refer to Operating Mode Tutorial for more
information.
Parameter Typical Return
CURRent|VOLTage, *RST VOLTage CURR or VOLT
Selects currentpriority regulation mode: FUNC CURR, (@1)
Keysight N6705C Operating and Service Guide 287
7 SCPI Programming Reference